Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 185: 488-94, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-25952897

RESUMO

The present work proposes a method for the direct determination of Al, Cu, Cr, Fe and Ni in Brazilian carbonated soft drinks by electrothermal atomic absorption spectrometry (ETAAS). Samples of different flavors packed in containers made of different materials (polyterephthalate ethylene and glass bottles, and aluminum and steel cans) were analyzed. The method was optimized by building up pyrolysis and atomization curves in sample medium and by evaluating the calibration approach. Under optimized conditions, recoveries in the range of 92-104% were obtained in the evaluation of method accuracy. The limits of quantification for Al, Cu, Cr, Fe and Ni were 2.3, 0.93, 0.17, 0.90 and 1.2 µg L(-1), respectively. Also, the impact of the material used in the packaging and flavor on the concentrations of each metal in the samples was evaluated. It was proved that neither flavor nor packaging material affected the concentrations of Al and Fe in the samples. On the other hand, the packaging material influenced the concentration of Cu, Cr and Ni, and only the flavor affected the concentration of Cu in the samples. These conclusions were based on the data obtained from the application of a two-way ANOVA evaluation at 95% confidence level.


Assuntos
Alumínio/análise , Cromo/análise , Cobre/análise , Ferro/análise , Níquel/análise , Brasil , Calibragem , Bebidas Gaseificadas/análise , Análise de Alimentos , Limite de Detecção , Espectrofotometria Atômica
2.
J Hazard Mater ; 181(1-3): 485-90, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20605324

RESUMO

In the present work, a new spectrophotometric method was developed for the determination of aluminum in soda drinks packed in different materials. Reaction among Al(III), phenylfluorone (PF) and cetylpyridinium chloride (CPC) in slightly alkaline medium was explored for this purpose. The method was optimized regarding to its chemical parameters in order to establish better conditions in terms of sensitivity and selectivity. The results obtained showed that the concentration of CPC presented remarkable influence on the sensitivity and acted as a sensitizer for the studied system. The possible interferences of some metallic cations were evaluated and the cations Cu(II), Mn(II), and Zn(II) presented noticed interference on the Al(III) signal. So, their interference was eliminated by using EDTA with minimum loss of sensitivity. The results obtained in the determination of total aluminum in soda drinks by the developed methodology were not statistically different from those obtained by electrothermal atomic absorption spectrometry. In the optimized conditions the method presented a linear range of 5-100 microg L(-1). The limits of detection and quantification were 0.81 and 2.7 microg L(-1), respectively. The methodology was successfully applied in the determination of aluminum in 10 samples of soda drinks packed in cans and plastic bottles.


Assuntos
Alumínio/análise , Bebidas/análise , Embalagem de Produtos , Cetilpiridínio , Fluoresceínas , Limite de Detecção , Metais Pesados/análise , Plásticos , Espectrofotometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...